O.E.M. Industrial Telemetry Products


A full range of cutting edge telemetry products have been developed to enable seamless integration with O.E.M. products.

forktrack

FM1 System Features

  • CANBus vehicle integration capability for plug and play installations
  • Analogue and digital IO for vehicle integration
  • Safety interlocks
  • Inbuilt 3-axis impact sensing
  • Integrates with operator swipe card accessories
  • Wi-Fi and GSM Telemetry Communication
  • Access to Level 1 reporting

Design Parameters

  • Dimensions: 110mm (L) x 80m (W) x 50mm (H)
  • PCB fully resin dipped
  • Non-volatile RAM memory storage
  • Capable of remote/over the air (OTA) firmware updates

Electrical characteristics

  • Nominal operating voltage: 12-96V DC
  • Operating voltage range: 4.5V DC – 112V DC
  • Operating current consumption (Average): 350mA @ 12V DC, 100mA @ 60V
  • Quiescent current consumptions: 25mA @ 12V DC, 25mA @ 60V DC

Environmental Parameters

  • Rated to IP 65 or better
  • Storage temperature: -40oC to 75oC
  • Nominal operating temperature: -10oC to 70oC

Technical Features

  • Two wire CAN Bus port hardware layer compliant to J1939, and CANOpen
  • Two wire CAN Bus auxiliary port (level 2 or 3 device port)
  • External RS-232 port
  • Quad-band GPRS modem or 802.11 B/G/N Wi-Fi modem
  • Three axis accelerometer (impact sensor)
  • Ten (0 – 15V) variable voltage and frequency inputs tolerate to 100V
  • Real time clock
  • Two processor controlled relays
  • Two processor controlled 12V digital outputs

FM2 System Features

  • Digital display and buzzer for visual/audio feedback
  • Pre-operational checklists
  • Real time operator speed alerting
  • Integration to active speed limiting products
  • Additional analogue and digital IO for weigh and lift accessory integration
  • Access to level 1 and 2 reporting

Design Parameters

  • 12 pin DTM, head connector, LCD, capacitive buttons
  • Dimensions: 101mm (L) x 84mm (W)
  • Non-volatile RAM memory storage
  • Full communication with FM1 device

Electrical Characteristics

  • Input voltage rating 5Vdc to 25Vdc
  • Operating current consumption (Average) 350 mA @ 12Vdc
  • Quiescent current consumption less than 15 mA @ 12Vdc

Environmental Parameters

  • Rated to IP 65 or better
  • Storage temperature: -40oC to 75oC
  • Operation temperature: -30oC to 75oC

Technical Features

  • Two external RS-232 ports
  • Digital input 2V5, trigger level
  • Variable voltage and variable current measurement input
  • Frequency input (measuring 200 mA range 1 Hz to 6500Hz)
  • Real time clock
  • Three processor controlled 12C digital outputs

Reporting Options

Speedshield offer various reporting level packages which complement their relative hardware. Level 1 reporting is included with FM1 hardware. Level 2 reporting requires the FM1 and FM2 hardware combination. Level 3 includes all reporting features with the total energy management hardware.

Reporting Level 1

Level 1 reporting provides basic reports for fleet managers to have visibility on the service side of the fleet and possible instances of damage.

  • Fleet utilisation
  • Vehicle fault code and diagnostics
  • Operator access and benchmarking
  • Impact reporting
  • Safety interlock compliance
  • Hour meter readings
  • Distance travelled

Reporting Level 2

Level 2 reporting provides extended reporting which requires a digital display and includes detailed operator reporting.

  • Pre-operational checklist history
  • Speed compliance
  • Load and lift performance
  • Vehicle GPS location and trail
  • All accessory add on reporting

Reporting Level 3

Level 3 reporting focuses on battery electric vehicles to provide information on energy utilisation and costs, real-time battery condition and fleet carbon footprint.

  • Fleet energy usage
  • Carbon footprint analysis
  • Battery charging history
  • Temperature, water levels, change rates (level of sulphation)
    • Cost per hour per charge